The building code doesn't say ADU
Massachusetts' building code (780 CMR, 10th Edition, the only code in effect since June 30, 2025) regulates dwelling units. Being an ADU for zoning waives nothing.
- Inside or attached
- A true second unit in or on a single-family house makes it a two-family under the Residential Code. The units are separated by 1-hour fire-rated wall and floor assemblies (1/2-hour if the whole building is sprinklered), with walls running from the foundation to the underside of the roof sheathing.
- Detached
- Built under the Residential Code to the standard of a new single-family home. Its exterior walls don't need a fire rating just because it shares the lot.
- Bedrooms
- A room that newly becomes a bedroom needs an emergency escape window. Massachusetts allows 3.3 sq ft of net clear opening, at least 20 in by 24 in, for double-hung and single-hung windows.
- Alarms and ceilings
- Photoelectric smoke alarms and CO alarms in the new unit. Ceilings at least 7 ft in habitable rooms; 6 ft 8 in for bathrooms, laundry and habitable basement space.
- Already a two-family?
- Adding a unit to an existing two-family is a change of occupancy to R-2 under the Commercial and Existing Building Codes, which can trigger major upgrades. That one needs an existing-building report up front.